View Catalogue
Machine Monitoring
System
VMRS 200 Series
The VMRS 200 is a product that best reflects VMS's philosophy of providing simple and cost-effective solutions
for detecting machine failures without the need for expert assistance.
The VMS Machine Monitoring System (MMS) VMRS 200 is a user-friendly system that notifies you
of rotating machinery failures or abnormalities through vibration values, without the need for complex software.
It can cover up to 4 channels and is compatible with other sensors in addition to vibration sensors.
Depending on the option, it can support up to 32 channels.
This product series has evolved from the VMRS 200W series to include various products lines.
VMRS 200W
Descriptions
The first developed VMRS 200W is a stand-alone type and has been sold under its own brand or as an OEM product,
which has been proven and tested in many places. It has machine monitoring and protection functions,
providing alarms or warnings in case of failures or abnormalities.
The protection function in MMS can activate the contact relay when an equipment abnormality is detected through alarms or dangers,
allowing the machine to stop or send an external signal. The system converts vibration input signals to display vibration velocity,
acceleration, acceleration enveloping or displacement values, depending on the module selection.

The raw vibration signals can be easily accessed and extracted from the front panel BNC connectors and the internal terminal block.
Features
  • Up to 4 of Dynamic simultaneous monitoring
  • With Alert and Danger as two independent set points and contact relay outputs for each channel
  • Selectable Individual channel live bar-graph displays
  • Programmable Alert or Danger Level
  • Isolated 4-20mA output signals (Optional)
  • Buffered raw output signals
Power requirement
Input voltage 85 ~ 264VAC
Input Frequency 47 ~ 63 Hz
Safety standard EN 60950-1
Signal Input
Sensor Accelerometer, Velocity transducer, Eddy-probe
Analogue input 4 ~ 20 mA, 1~ 5 VDC
Sensor sensitivity Selectable via Jumper
Sensor OK detection Continuous monitoring of the MMS bias and signal voltage.
If voltage exceeds preset limits, the 4 to 20mA output currents is
reduced to less than 2mA.
Output
Buffered output 4-BNC connector, Screw terminals
Buffered output Sensitivity Same as a sensor sensitivity
Screw terminal output Sensitivity Same as a sensor sensitivity
Sensor sensitivity Selectable via Jumper
Accuracy Typ. ±1% of full-scale range
Analogue Output Isolated 4~20mA
Relay rating - max switching voltage 250 VAC
Relay rating - max switching current 5A
System Configuration